INTENSIFICATION OF THE HEAT TRANSFER THROUGH CORRUGATED WALL
Abstract
The corrugation of the smooth steel tubes increases the heating surface per length unit. The advantages compared to smooth pipe bodies are the lower relative mass at same thermal power and the smaller volume. The aim of the present research is to trace the temperature alteration near to a specially corrugated wall with baffles. The baffles have variable step towards the flow direction at two different heights. We observe developed turbulent air flow at temperature 353К (80oC) through a corrugated tube with inside diameter d=0.08m and length 0.2m. The tube wall is heated to 453K (180oC). The heat transfer between the tube and the flowing fluid has been modulated at two different corrugation grades of the tube – Х 1 and Х 2 – equation (9) and with four different Reynolds numbers.
Full Text:
PDFRefbacks
- There are currently no refbacks.
Food and Environment Safety by Stefan cel Mare University of Suceava is licensed under a Creative Commons Attribution 4.0 International License.
Online ISSN: 2559 - 6381
Print ISSN: 2068 - 6609